Cummins Fault Code
Free · no signup1896 (SPN 2791 FMI 13)
Power loss (derate); Black smoke; Rough idle; Increased soot load in DPF.
System
Not specified
Symptom
Power loss (derate); Black smoke; Rough idle; Increased soot load in DPF.
Diagnosis & fix steps
EGR Valve Controller - Out of Calibration.
LOGIC: EGR Valve calibration failure. Valve cannot reach fully open or closed stops due to soot or mechanical wear.
ACTION: Inspect for carbon buildup in the valve throat. Perform "EGR Valve Calibration" test via scan tool. Check for binding.
FIX: Clean carbon from valve and seat; replace EGR Valve assembly if internal gears are stripped.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.