Hidromek Fault Code
Free · no signupCode 31-08
Hydraulics Stiff / Loader Lift Weak
System
Hydraulics
Symptom
Hydraulics Stiff / Loader Lift Weak
Diagnosis & fix steps
LOGIC: Unloader Valve Solenoid Circuit Electrical Failure.
ACTION: Check dual-gear pump unloader solenoid coil resistance on the loader valve block. Verify 12V supply feed from the cab dashboard auxiliary switch.
Red Seal field insights
Pump Merging: System uses an electronic unloader valve to combine or isolate dual hydraulic pump flows; a dead solenoid locks the system in low-flow single-pump mode.
Same code keeps coming back?
That's a program problem, not a part problem. Book a 30-minute uptime review with Grant, a Red Seal Heavy Duty Technician.
Read before you touch anything
- This is general reference information, not a repair manual. It is for trained, qualified technicians.
- Fault codes, meanings and procedures vary by model, serial number and software version. Confirm the code and the procedure against the manufacturer's service manual before acting.
- Follow the OEM service manual, torque specs and your site's safety procedures: lockout/tagout, block raised equipment, relieve hydraulic, fuel and air pressure, and let hot systems cool.
- You use this information at your own risk. Adventure Mechanical and AM Fleet Integrity accept no liability for damage, injury, downtime or loss arising from its use.
- Not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the equipment a code applies to.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.
Start your free trial