Komatsu Fault Code
Free · no signupDGH2KB
Cluster Temp Warning / Auto-Idle Inop
System
Sensors / Thermal
Symptom
Cluster Temp Warning / Auto-Idle Inop
Diagnosis & fix steps
LOGIC: Hydraulic Oil Temperature Sensor Ground Short.
ACTION: Disconnect 2-pin temperature sender on hydraulic tank side. Measure thermistor resistance (spec: ~3.5k–90kΩ depending on temp); trace harness along tank wall for pinch points against the cab floor frame.
Red Seal field insights
Failsafe Temp Hold: When shorted to ground, the controller fixes the calculated hydraulic temp value at 40°C, disabling high-temperature hydraulic protection curves and cooling fan adjustments.
Same code keeps coming back?
That's a program problem, not a part problem. Book a 30-minute uptime review with Grant, a Red Seal Heavy Duty Technician.
Read before you touch anything
- This is general reference information, not a repair manual. It is for trained, qualified technicians.
- Fault codes, meanings and procedures vary by model, serial number and software version. Confirm the code and the procedure against the manufacturer's service manual before acting.
- Follow the OEM service manual, torque specs and your site's safety procedures: lockout/tagout, block raised equipment, relieve hydraulic, fuel and air pressure, and let hot systems cool.
- You use this information at your own risk. Adventure Mechanical and AM Fleet Integrity accept no liability for damage, injury, downtime or loss arising from its use.
- Not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the equipment a code applies to.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.
Start your free trialRelated Komatsu fault codes
- DHPAMAHydraulic Drift / Error Code Active
- Code 52-11Propulsion Cutout / Blower Warning
- Code 2301 / A2301Hoist Body Inoperative / Dump Locked
- DX19KZTravel Motor Shift Malfunction / Active E03 Alarm
- CA559 / SPN 157 FMI 18Power Cut under Load / Stalling
- DXE5KASlow Attachment Movement / No Pump Merge
- CA559Derate / Engine Stalls
- E012 / CA2384Swing Function Soft / Heavy Machine Lug
- E02Pump Contol Error.
- CA2249 / P228CDerate / Engine Stumble