Epiroc Fault Code
Free · no signupSPN 522765 FMI 04
Secondary Steering Siren Stays Active
System
Steering / Emergency
Symptom
Secondary Steering Siren Stays Active
Diagnosis & fix steps
LOGIC: Ground-Driven Emergency Steering Flow Switch Short to Ground.
ACTION: Remove flow switch from emergency steering pump discharge manifold. Test switch continuity while manually moving the internal flow paddle; inspect harness for ground rub-through.
Red Seal field insights
False Alert: A grounded circuit tricks the RCS into reading continuous emergency pump flow, falsely flagging primary steering pump failure and locking on the cab siren.
Same code keeps coming back?
That's a program problem, not a part problem. Book a 30-minute uptime review with Grant, a Red Seal Heavy Duty Technician.
Read before you touch anything
- This is general reference information, not a repair manual. It is for trained, qualified technicians.
- Fault codes, meanings and procedures vary by model, serial number and software version. Confirm the code and the procedure against the manufacturer's service manual before acting.
- Follow the OEM service manual, torque specs and your site's safety procedures: lockout/tagout, block raised equipment, relieve hydraulic, fuel and air pressure, and let hot systems cool.
- You use this information at your own risk. Adventure Mechanical and AM Fleet Integrity accept no liability for damage, injury, downtime or loss arising from its use.
- Not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the equipment a code applies to.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.
Start your free trialRelated Epiroc fault codes
- SPN 522770 FMI 02Steering Inoperative / Red Warning
- SPN 522760 FMI 05Steering Response Dead / Warning Siren
- SPN 522775 FMI 04Rough Ride / Front Suspension Bounces
- SPN 522755 FMI 14Payload Telemetry Frozen / Incorrect
- SPN 522780 FMI 05Engine & Hydraulic Temperatures Creep High
- SPN 522750 FMI 05Zero Implement Response / Lever Dead
- SPN 522785 FMI 02Engine Idles / Machine Refuses to Tram
- SPN 522745 FMI 04Bucket Dump Dead / Curl Operation Slow
- SPN 522790 FMI 04Lube Warning Active / Dry Hitch Pins
- SPN 522740 FMI 03Boom Lifts Uncommanded / Safety Alarm