Hitachi Fault Code
Free · no signup11304-3
Bucket Dump Function Sluggish
System
Hydraulics
Symptom
Bucket Dump Function Sluggish
Diagnosis & fix steps
LOGIC: Bucket Dump Pilot Pressure Sensor Signal Voltage High.
ACTION: Inspect pilot line pressure sensor harness for short to 5V reference. Connect mechanical gauge to pilot block to check actual pressure against sensor sweep.
Red Seal field insights
Regeneration Lock: A 5V signal ceiling leads the machine controller to assume full operator pilot demand at all times, disabling hydraulic regeneration circuits.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.
Start your free trial