Sinotruk Fault Code

Free · no signup

P0193 / SPN 157 FMI 3

Check Engine Solid / Fixed Fuel Trim

System

Sensors / Fuel

Symptom

Check Engine Solid / Fixed Fuel Trim

Diagnosis & fix steps

LOGIC: Rail Pressure Sensor Circuit Voltage High (Open Ground / Ceiled). ACTION: Inspect 3-pin connector on common rail. Measure signal wire voltage (key-on, unplugged: 5V pull-up; plugged: 0.5–1.0V). Verify sensor ground circuit back to EDC17 engine ECM pin.

Red Seal field insights

Vibration Fretting: Engine shaking fatigues the sensor terminal pins; an open sensor ground wire floats the output to 5V, forcing the ECM to run on default fuel tables.

Same code keeps coming back?

That's a program problem, not a part problem. Book a 30-minute uptime review with Grant, a Red Seal Heavy Duty Technician.

Book an uptime review

Read before you touch anything

  • This is general reference information, not a repair manual. It is for trained, qualified technicians.
  • Fault codes, meanings and procedures vary by model, serial number and software version. Confirm the code and the procedure against the manufacturer's service manual before acting.
  • Follow the OEM service manual, torque specs and your site's safety procedures: lockout/tagout, block raised equipment, relieve hydraulic, fuel and air pressure, and let hot systems cool.
  • You use this information at your own risk. Adventure Mechanical and AM Fleet Integrity accept no liability for damage, injury, downtime or loss arising from its use.
  • Not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the equipment a code applies to.