Detroit Diesel Fault Code

Free · no signup

SPN 5397 FMI 31

Active DPF Light / High Fuel Burn

System

Emissions / DPF

Symptom

Active DPF Light / High Fuel Burn

Diagnosis & fix steps

LOGIC: DPF Regeneration Frequency Too High (Excessive Regens). ACTION: Perform oil sample test for fuel dilution. Inspect engine for leaking injectors, oil passing turbo seals, or worn valve stem seals.

Red Seal field insights

Root Cause Warning: Frequent regens indicate excessive soot or oil dumping into exhaust rather than a faulty DPF filter.

Track this across your whole fleet

This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.