Kobelco Fault Code
Free · no signupMC1-W16
Warning Buzzer. Pilot pressure fluctuates; slow brake release.
System
Not specified
Symptom
Warning Buzzer. Pilot pressure fluctuates; slow brake release.
Diagnosis & fix steps
Accumulator Pressure Low (Front Drum).
LOGIC: The pressure in the nitrogen-charged accumulator for the front drum circuit has dropped below 3.4 MPa.
ACTION: Check the nitrogen gas charge in the accumulator. Recharge or replace the bladder.
Red Seal field insights
Pro-Tip: W16 and W17 usually indicate a blown bladder. If you find hydraulic oil coming out of the nitrogen gas valve, the bladder is gone.
Same code keeps coming back?
That's a program problem, not a part problem. Book a 30-minute uptime review with Grant, a Red Seal Heavy Duty Technician.
Read before you touch anything
- This is general reference information, not a repair manual. It is for trained, qualified technicians.
- Fault codes, meanings and procedures vary by model, serial number and software version. Confirm the code and the procedure against the manufacturer's service manual before acting.
- Follow the OEM service manual, torque specs and your site's safety procedures: lockout/tagout, block raised equipment, relieve hydraulic, fuel and air pressure, and let hot systems cool.
- You use this information at your own risk. Adventure Mechanical and AM Fleet Integrity accept no liability for damage, injury, downtime or loss arising from its use.
- Not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the equipment a code applies to.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.
Start your free trialRelated Kobelco fault codes
- MC1-W17Warning Buzzer. Brake timing feels "off"; choppy controls.
- MC1-A03Function Lock. The crane prevents certain movements; "Unload Valve" error.
- P0191Hunting Idle / Power Loss
- M01-A03Hoist-up function cut off; Continuous alarm; LMI indicates "Two-Block."
- P0500Winch/Travel Speed Fault
- L01-A03Safety Lock.
- 114-3Travel Speed Stuck in Low