Liebherr Fault Code
Free · no signupP1195
DPF Warning Light / High Idle
System
Emissions / DPF
Symptom
DPF Warning Light / High Idle
Diagnosis & fix steps
LOGIC: DPF Differential Pressure Above Max Operating Limit (Soot Level 3).
ACTION: Perform active forced DPF regeneration via SCULI diagnostic tool. Inspect differential pressure sensor sample tubes for soot clogging or moisture.
Red Seal field insights
Exhaust Backpressure: High soot accumulation increases backpressure, restricting turbo spooling and forcing active regeneration to prevent filter cracking.