Sany Fault Code
Free · no signupSPN 520201 FMI 5
Auxiliary Hydraulics Inoperative
System
Hydraulics
Symptom
Auxiliary Hydraulics Inoperative
Diagnosis & fix steps
LOGIC: Auxiliary Proportional Valve Solenoid Current Below Normal (Open Circuit).
ACTION: Check solenoid valve coil resistance on auxiliary hydraulic manifold. Inspect harness lead running along loader lift arm for wire snaps.
Red Seal field insights
Current Loop: SYMC detects zero current draw, identifying a broken wire filament, loose connector, or open solenoid coil.
Same code keeps coming back?
That's a program problem, not a part problem. Book a 30-minute uptime review with Grant, a Red Seal Heavy Duty Technician.
Read before you touch anything
- This is general reference information, not a repair manual. It is for trained, qualified technicians.
- Fault codes, meanings and procedures vary by model, serial number and software version. Confirm the code and the procedure against the manufacturer's service manual before acting.
- Follow the OEM service manual, torque specs and your site's safety procedures: lockout/tagout, block raised equipment, relieve hydraulic, fuel and air pressure, and let hot systems cool.
- You use this information at your own risk. Adventure Mechanical and AM Fleet Integrity accept no liability for damage, injury, downtime or loss arising from its use.
- Not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the equipment a code applies to.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.
Start your free trialRelated Sany fault codes
- SPN 520202 FMI 3Heavy Engine Lugdown / High Smoke
- SPN 520201 FMI 04Slow Implement Speeds / Zero Hydraulic Gain
- SPN 520205 FMI 4Main Boom Raise Extremely Slow
- SPN 520200 FMI 03Engine Bogs / Stall on Implement Demand
- SPN 520217 FMI 03Power Boost Button Dead / Low Breakout
- E402Boom Kick-out / Return-to-Dig Dead
- SPN 520203 FMI 05Hydraulic & Coolant Temperature Creep
- SPN 3509 FMI 4Multiple Sensor Faults Active
- SPN 520206 FMI 03Boom Lift Slow / No Confluence
- SPN 3364 FMI 1Active Derate Countdown Warning