Sany Fault Code
Free · no signupSPN 520217 FMI 03
Power Boost Button Dead / Low Breakout
System
Hydraulics
Symptom
Power Boost Button Dead / Low Breakout
Diagnosis & fix steps
LOGIC: Main Relief Pressure High Solenoid (Power Boost) Short to Power.
ACTION: Measure power boost solenoid coil resistance on the main relief valve block. Trace wire harness to the right-hand joystick push-button switch for pinched conductors.
Red Seal field insights
Pressure Safeguard: The SYMC controller disables power boost stage actuation (raising system pressure from 34.3 MPa to 37.3 MPa) to protect the main valve block from permanent over-pressure.
Same code keeps coming back?
That's a program problem, not a part problem. Book a 30-minute uptime review with Grant, a Red Seal Heavy Duty Technician.
Read before you touch anything
- This is general reference information, not a repair manual. It is for trained, qualified technicians.
- Fault codes, meanings and procedures vary by model, serial number and software version. Confirm the code and the procedure against the manufacturer's service manual before acting.
- Follow the OEM service manual, torque specs and your site's safety procedures: lockout/tagout, block raised equipment, relieve hydraulic, fuel and air pressure, and let hot systems cool.
- You use this information at your own risk. Adventure Mechanical and AM Fleet Integrity accept no liability for damage, injury, downtime or loss arising from its use.
- Not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the equipment a code applies to.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.
Start your free trialRelated Sany fault codes
- SPN 806 FMI 1Hydraulic Oil Level Low.
- SPN 520205 FMI 4Main Boom Raise Extremely Slow
- SPN 520202 FMI 3Heavy Engine Lugdown / High Smoke
- SPN 520201 FMI 5Auxiliary Hydraulics Inoperative
- SPN 520201 FMI 04Slow Implement Speeds / Zero Hydraulic Gain
- SPN 520200 FMI 03Engine Bogs / Stall on Implement Demand
- SPN 520220 FMI 03Boom Lifts Uncommanded / Safety Cut
- SPN 520215 FMI 04Bucket / Boom Joysticks Inoperative
- SPN 520220 FMI 04Hydraulic Temp Gauge Pinned / False Warning
- SPN 520214 FMI 02Hydraulic Controls Sluggish / Soft Deadband