Liebherr Fault Code

Free · no signup

0x0114

Upper Carriage Slew Locked / Drift Alarm

System

Hydraulics / Slew

Symptom

Upper Carriage Slew Locked / Drift Alarm

Diagnosis & fix steps

LOGIC: Slew Gearbox Hydraulic Holding Brake Solenoid Circuit Open. ACTION: Disconnect multi-disc brake release solenoid on the swing drive reduction box. Measure coil resistance (spec: ~24Ω). Check 24V supply output from Litronic driver module +4A1-A1 pinout.

Red Seal field insights

Negative Brake: Spring-applied, hydraulically released multi-disc brakes clamp automatically when de-energized; an open circuit prevents hydraulic release, deadheading swing pumps.

Track this across your whole fleet

This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.