Liebherr Fault Code
Free · no signup0x015A
Winch Down Speed Limited / Creep
System
Hydraulics / Winch
Symptom
Winch Down Speed Limited / Creep
Diagnosis & fix steps
LOGIC: Dragline / Clamshell Winch Secondary Holding Brake Pressure Low.
ACTION: Measure pilot pressure at the mechanical brake release port with a 0–60 bar gauge. Inspect the proportional brake release solenoid valve on the winch base block for foreign contamination.
Red Seal field insights
Safety Valve: If pilot release pressure drops below 28 bar, Litronic limits down-spooling speed to prevent cable backlash and uncontrolled bucket dropping.
Track this across your whole fleet
This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.