Liebherr Fault Code

Free · no signup

0x015A

Winch Down Speed Limited / Creep

System

Hydraulics / Winch

Symptom

Winch Down Speed Limited / Creep

Diagnosis & fix steps

LOGIC: Dragline / Clamshell Winch Secondary Holding Brake Pressure Low. ACTION: Measure pilot pressure at the mechanical brake release port with a 0–60 bar gauge. Inspect the proportional brake release solenoid valve on the winch base block for foreign contamination.

Red Seal field insights

Safety Valve: If pilot release pressure drops below 28 bar, Litronic limits down-spooling speed to prevent cable backlash and uncontrolled bucket dropping.

Track this across your whole fleet

This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.

Start your free trial