Liebherr Fault Code

Free · no signup

0x028A

Main Shovel Digging Force Weak

System

Hydraulics

Symptom

Main Shovel Digging Force Weak

Diagnosis & fix steps

LOGIC: Main Working Pump Swashplate Angle Feedback Deviation. ACTION: Inspect dual rotary angle position transducers mounted on the main Rexroth A4VSO pump heads. Check 24V power supply and recalibrate swashplate zero/span via Litronic.

Red Seal field insights

Closed-Loop Displacement: Prevents hydraulic pump cavitation or over-stroking by ensuring physical pump displacement precisely tracks operator demand and engine torque curves.

Track this across your whole fleet

This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.

Start your free trial