Liebherr Fault Code

Free · no signup

E 310

PDE Recording Drops / Display Misconfiguration

System

Control / CAN

Symptom

PDE Recording Drops / Display Misconfiguration

Diagnosis & fix steps

LOGIC: Hardware/Software Configuration Mismatch (TREAGER parameter set improperly). ACTION: Verify parameters in Litronic 'Set' menu. Ensure drilling configuration is set to ON and input X50.15 on the BBT module is grounded.

Red Seal field insights

Rig Configuration: Litronic controllers use pin grounding to differentiate standard excavators from drilling rigs; ungrounded pins drop Process Data Recording (PDE).

Track this across your whole fleet

This code is free to read. AM Fleet Integrity lets your team log fault codes against assets, plus the full fault-code library, QR operator reporting, PM scheduling and predictive alerts. Start free — no credit card required.

Start your free trial