Liebherr Fault Code
Free · no signupE 310
PDE Recording Drops / Display Misconfiguration
System
Control / CAN
Symptom
PDE Recording Drops / Display Misconfiguration
Diagnosis & fix steps
LOGIC: Hardware/Software Configuration Mismatch (TREAGER parameter set improperly).
ACTION: Verify parameters in Litronic 'Set' menu. Ensure drilling configuration is set to ON and input X50.15 on the BBT module is grounded.
Red Seal field insights
Rig Configuration: Litronic controllers use pin grounding to differentiate standard excavators from drilling rigs; ungrounded pins drop Process Data Recording (PDE).